Nice move! I think you have it correctly mounted though, I wouldn’t put it on a bracket. I used a conversion bracket for direct drive on my Max and I kept getting pulsing issues.

I think they were due to the filament pushing down the hotend slightly when starting to extrude because the hotend is mounted on the compliant strain gauge mount. With your method, it stays isolated and doesn’t push down more on the strain gauge mount when the extrusion starts.

Please give me an update if you can if you run into any other problems!